Accuracy

Accuracy

As a standard, the SSP II works from 0.1 MPa pressure up. It signals the liquid leakage approximately within 30 sec to 3 minutes, always with the leakage localization accuracy at tens of meters order.

The SSP II will be always adapted to needs of the operator and to technical parameters of the route monitored, i.e. it will be solved for a particular project. Sensitivity of the SSP II system depends on the pipeline diameter and on the value of pressure difference between the medium and the pipeline environs. For example at 5000 kPa pressure it is possible to detect the holes of ca 2 mm diameter and leakage of 0.3 l/sec on the piping of DN300, at pressure of 1000 kPa the values are 5 mm for the hole diameter and 0.6 l/sec for the leakage, see table of pressures, holes and leakage detected.